Ethernet Oam Configuration Settings - D-Link xStack DES-3528 series User Manual

Layer 2 managed stackable fast
Hide thumbs Also See for xStack DES-3528 series:
Table of Contents

Advertisement

®
xStack
DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual

Ethernet OAM Configuration Settings

This window is used to configure and display the primary controls and status information for Ethernet OAM on the
Switch.
To view this window, click L2 Features > Ethernet OAM > Ethernet OAM Configuration Settings as shown below:
The following parameters can be configured:
Parameter
Description
From Port / To
Specify a range of ports to be configured.
Port
Link Event
Configures the Ethernet OAM critical link event. Specify Link Monitor or Critical Link Event.
Link Monitor
Indicates that the OAM entity can send and receive Event Notification OAMPDUs.
Threshold
Specify the number of error frame per second in the period that is required to be equal to or
(0-4294967295)
greater than the value of the special threshold in order for the event to be generated. The default
value of threshold is 1 error frame per second.
Window
Specify the period of error frame summary events. The range is 1000ms-60000ms and the
(1000-60000)
default value is 1000 ms.
Notify
Specify to Enable or Disable the event notification. The default state is Enabled.
Click Apply to implement changes.
Figure 3 - 94 Ethernet OAM Configuration Settings window