List Of Live Streaming Error Displays K - JVC GY-HM200U Instruction Manual

4k memory card camera recorder
Hide thumbs Also See for GY-HM200U:
Table of Contents

Advertisement

List of Live Streaming Error Displays K

The following error messages are displayed when the live streaming setting is incorrect, or when the
connection is lost during live streaming.
Error message
Invalid Address.
Multicast Is Not Supported.
Cannot Connect to Receiver. Establishment of connection with
TCP Disconnected.
Not Enough Bandwidth.
Connection Timeout
Authorization Failed
Connection Error
Disconnected
Status
The IP address format is
0
incorrect.
The domain name cannot be
0
converted into the IP address.
An IP multicast address was set.
TCP failed.
TCP connection is lost.
The communication bandwidth
0
is narrower than the average bit
rate.
The network bandwidth is
0
insufficient, and packets are
discarded.
Timeout for connection via ZIXI.
Authentication of connection via
ZIXI failed.
Connection via "ZIXI" or "RTMP"
failed.
"ZIXI" or "RTMP" connection is lost. Check whether there is abnormality
Action
Enter the IP address, host name
0
or URL of the destination
correctly.
(A P168 [Setting Distribution] )
Use an IP address that is not a
multicast address.
Ensure that the recipient's
0
device is set to TCP.
Set Type to "MPEG2-TS/UDP".
0
(A P168 [Setting Distribution] )
Check to ensure that there is no
abnormality in the decoder, or
network connection device and
cables, followed by establishing the
connection again.
Lower the resolution/picture
0
quality of the video to be
distributed.
Consider switching to the use of
0
a stable network, such as wired
LAN.
Set [Destination Address] and
[Destination Port] correctly.
(A P168 [Setting Distribution] )
Set [Stream ID] and [Password]
correctly.
(A P168 [Setting Distribution] )
Check whether a different
0
camera with an identical stream
ID is connected.
Set [Destination URL] and
0
[Stream Key] correctly.
(A P119 [ Destination URL ] )
(A P119 [ Stream Key ] )
with the network connection device,
cables, etc., and try to re-establish
the connection.
Error Messages and Actions
173

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-hm200eGy-hm170uGy-hm170e

Table of Contents