Diagnostic Test - LG GD1329CGS Service Manual

Lg gd1329cgs; gd1329ces; gd1329cgu; gd1329ceu; gd1329cgd; gd1329ced; gd1329qgs; gd1329qes; gd1329qgu; gd1329qeu; gd1329qgd; gd1329qed electric & gas dryer
Hide thumbs Also See for GD1329CGS:
Table of Contents

Advertisement

15

DIAGNOSTIC TEST

1.This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified.
2.Activating the heater manually with the door open may trip the thermostat attached to the heater, therefore do
not activate it manually. (Do not press the door switch to operate the heater while the door is open).
Diagnostic test:
This program has been added for testing the dryer and detecting errors.
Entering the test mode
Data Name
1. Entering programming mode
Entering
2. WHITES AND COLORS
the test mode
3. START
1 1
Pressing the START button cycles to the next test function.
Number of times the START
button is pressed
None
1 time
2 times
3 times
4 times
5 times
6 times
During check, if the door is open.
During check, if the door is closed
Note
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
(display)
Button
Display
Checking point
Check the version and code of machine.
ELECTRIC TYPE : US:OE
GAS TYPE : US:Og
Motor runs.
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
GAS TYPE: GAS valve runs.
Motor + Valve
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
GAS TYPE: GAS valve runs.
Motor+Valve
LED & KEY CHECK
Press WHITES AND COLORS button.
Press PERMANENT PRESS button.
Press DELICATES button.
Test ends.
Door switch
(Motor & Heater Off, Buzzer beeps seven
times)
Test goes back at step 2.
(Motor on & Heater Off)
Insert service card (card type), Turn on/off toggle switch (Coin type).
Press the WHITES AND COLORS button. Then
display.
Enter the diagnostic test mode.
LqC 1
Version and code of machine (All LED on)
Display US:OE or US:Og and gU:XX
alternately. XX is the version number.
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Version and code of machine
LqC 1
dE
(The door is open. Please close the door
completely)
Measured moisture value (70~239)
47
Description
appears in the
Display

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents