General Control of Refrigerating Cycle
NO.
ITEMS
UNIT
1
Pipe and
Min.
piping system
opening time
2
Welding
Nitrogen
pressure
3
N
sealed
Confirm
2
parts
N
leak
2
4
Refrige-
Evacuation
Min.
ration
time
Cycle
V acuum
T orr
degree
V acuum
EA
V acuum
EA
piping
Pipe
EA
coupler
Outlet
(Socket)
Plug
5
Refrigerant
EA
weighing
6
Drier
replacement
7
Leak check
STANDARDS
Pipe: within 1 hour.
Comp: within 10 minutes.
Drier: within 20 minutes.
Weld under Nitrogen
atmosphere.
(N
pressure:
2
0.1~0.2 kg/cm
2
)
Confirm the sound of
pressure relief when
removing the rubber cap.
Sound: usable
No sound: not usable
More than 40 minutes
Below 0.03 (ref)
High and low pressure sides
are evacuated at the same
time for models above 200 l.
Use R-134a manifold
exclusively.
Use R-134a manifold
exclusively.
R-134a manifold exclusively.
R-134a manifold exclusively.
Use R-134a exclusively.
Weighing allowance: ±5g
Note: Winter: -5g
Summer: +5g
- Use R-134a exclusively for
R-134a refrigerator.
- Replace drier whenever repairing
refrigerator cycle piping.
- Do not use soapy water for
check. It may be sucked
into the pipe by a vacuum.
- 16 -
PURPOSES
T o protect
The opening time should be reduced
moisture
to a half of the standards during rain
penetration.
and rainy seasons (the penetration of
water into the pipe is dangerous).
T o protect oxide
- Refer to repair note in each part.
scale formation.
- R-134a refrigerant is more
susceptible to leaks than R-12 and
requires more care during welding.
- Do not apply force to pipes before and
after welding to protect pipe from cracking.
T o protect
- In case of evaporator parts, if it doesn't
moisture
make sound when removing rubber
penetration.
cap, blow dry air or N
than 1 min. and than use the parts.
To remove moisture.
Note: Only applicable to the model
equipped with reverse flow
protect plate.
Vacuum efficiency can be improved
by operating compressor during
evacuation.
T o protect mixing
The rubber pipes for R-12 refrigerant
of mineral and
will be melted when they are used for
ester oils.
R-134a refrigerant (causes of leak.)
T o protect R-12
refrigerant mixing.
T o protect R-12
refrigerant mixing.
T o protect R-12
refrigerant mixing.
Do not mix with
- Do not weigh the refrigerant at too
R-12 refrigerant.
hot or too cold an area.
(77¡F [25¡C] is adequate.)
- Make Copper charging canister
(Device filling refrigerant)
Socket: 2SV Plug: 2PV R-134a
Note: Do not burn O-ring (bushing)
during welding.
T o remove the
moisture from
pipe inside.
Defect in
- Check for an oil leak at the refrigerant
refrigerant leak
leak area. Use an electronic leak
area.
detector if an oil leak is not found.
- The electronic leak detector is very
sensitive to halogen gas in the air. It
also can detect R-141b in urethane.
Practice many times before using this
type of detector to avoid false readings.
REMARKS