Lennox 61H42 Installation Instructions
Lennox 61H42 Installation Instructions

Lennox 61H42 Installation Instructions

Lennox international inc. solid state defrost replacement board installation instructions

Advertisement

Quick Links

HEAT PUMP KITS AND ACCESSORIES
©1993 Lennox Industries Inc.
502,673M
Dallas,Texas
9/93
Supersedes 3/92
Litho U,S,A.
SOLID STATE DEFROST
REPLACEMENT
BOARD
INSTALLATION
INSTRUCTIONS
FOR SOLID STATE DEFROST
REPLACEMENT
BOARD
LB-83114C
(61H42)
USED ON HP7-1,
-2,
HP8, CliP9
AND CliP10
SERIES
UNITS
,/SHIPPINGANDPACKING
_
: :
::
: ]
Package 1 of 1 contains:
1- Control board on mounting bracket
1- Defrost thermostat
1- Outdoor fan/defrost relay
8- Wires with 3/16" terminals
1- Screw
2- Wire nuts
/tNSTA_TiON:
:
1- Turn off power supply to unit.
2- Remove
compressor
access panel and control
box cover.
A- Defrost Thermostat
3- Disconnect
coil thermistor
from coil return bend
and air thermistor from fan section. Replace coil
thermistor
with
provided
defrost
thermostat.
Secure to liquid line as close as possible
to the
outdoor
coil.
NOTE-/t
may be necessary to remove the front corner
panel for access to coil thermistor,
B-Defrost
Board
4- Remove and retain screwfrom existing
solid state
defrost
board
located
in control
box.
Note
existing wiring. See figure 1.
5- Install newcontrol
board assembly using existing
screw and hole.
6- Drill new hole into control
panel and secure with
screw provided
in kit.
C-Outdoor
Fan/Defrost
Relay
7- Remove
outdoor
fan/defrost
relay.
Install
replacement
outdoor
fan/defrost
relay.
1- Connect one end of long wire (provided)
to "HLD"
terminal
on the defrost board. Disconnect
defrost
high pressure switch from between high pressure
switch and loss of charge switch.
2-Splice
remaining
end
of
long
wire
to
wire
between high pressure switch and toss of charge
switch where high pressure switch was originally
connected.
3- Connect onewire
from defrost relaycoitto
"OUT"
terminal
of defrost
board.
4- Cut off terminal
of remaining
wire from defrost
relay coil and strip wire 5/8 inch. At a convenient
location,
splice
wire to long wire
from
"HLD"
terminal
using a wire nut.
5- Connect wire from defrost
thermostat
to one of
the "24V" terminals
on defrost
board.
IMPORTANT-Make
sure defrost thermostat is securely
fastened to the fiquid line.
6-
Cut
off
terminal
from
remaining
defrost
thermostat
wire
and strip wire
5/8 inch. Splice
with one of the defrost
pressure
switch
wires
using a wire nut.
7-
Locate blue transformer
wire
and splice with
remaining
defrost
high
pressure
switch
wire
using a wire nut.
8- Connect the remaining
existing
wire to "COM"
terminal
on defrost
board.
9- Defrost time interval can be selected
to defrost
every 30, 60 or 90 minutes. This is selected using
the jumper
on the defrost
board.
10-Replace
all panels and restore power to unit.
Page 1

Advertisement

loading

Summary of Contents for Lennox 61H42

  • Page 1 ©1993 Lennox Industries Inc. Dallas,Texas INSTALLATION INSTRUCTIONS LB-83114C (61H42) ,/SHIPPINGANDPACKING Package 1 of 1 contains: 1- Control board on mounting bracket 1- Defrost thermostat 1- Outdoor fan/defrost relay 8- Wires with 3/16" terminals 1- Screw 2- Wire nuts /tNSTA_TiON: 1- Turn off power supply to unit.
  • Page 2 TOP VIEW REPLACEMENT BOARD REMOVE EXISTING BOARD HIGH PRESSURE SWITCH LOSS OF CHARGE SWITCH DEFROST BOARD COMPRESSOR CONTACTOR EXISTING TRANSFORMER COMMON YELLOW WIRE Use existing hole to install replacement ®1 Drill new hole into control box panel FIGURE 1 TYPICAL WIRING RST 0 24V * _)-...
  • Page 3 The defrost control is a solid state control manufacturedby Hamilton Standard.The control providesautomaticswitchingfrom normal heating operationto defrost mode and back.The defrost controlcontains a solidstatetimerwhich switches an externa] defrost relay through 1/4" male spades mountedon the control'scircuit board.Thecontrol energizes t he defrostrelay at regular timed intervals.
  • Page 4 DEFROST CONTROL START HERE Check control transformer primary and secondary voltages. Repair or replace as necessary. Turn off power to unit. Check defrost sensor. Is sensor temperature or pressure acti- vated? For help in determining, fer to operation of control in unit installation instructions and unit wiring diagram.