SETTINGS
External sync adjustment (VBS) (VCC-4592P only)
1
Connect the VBS signal output for the other camera to the VBS
IN connector at the rear of this camera.
2
If the signals are not synchronized, change the sub-carrier (SC-P1)
switches as follows.
Setting
Default
Set to 90˚ counterclockwise
Set to 180˚ counterclockwise
Set to 270˚ counterclockwise
H-P
Note:
•
The sub-carrier switches let you make broad adjustments to the
sub-carrier phase. If finer adjustments are required, contact the
place of purchase.
•
The type and length of the cable which is connected to the VBS
connector may cause the horizontal synchronization being out of
phase. If this happens, adjust VR304 (H-P: horizontal sync).
15
English
9-pin
OFF (down)
OFF
ON
ON
9
10
Lens iris adjustment
If using a DC type auto-iris lens, you will need to set the LEVEL
(VR301) volume when shooting in the conditions described below.
VR301
LEVEL
10-pin
OFF
ON (up)
L (counterclockwise): To decrease the contrast
OFF
H (clockwise): To increase the contrast
ON
•
If shooting simultaneously in a dark room and through a bright
window.
•
If the subject background is extremely bright or dark.
•
If the brightness of the picture on the monitor is not correct.