K2
ELECTRONIC
SYSTEM
COMPONENTS
ELECTRONIC
SYSTEM
COMPONENTS
HOLD SWITCH
Inspection
Inspection
of operation
-/
1. Turn the ignition
switch OFF-+ON.
2. Verify that the HOLD
indicator
is not illuminated.
Depress
the switch and verify that the HOLD
indicator
comes ON.
3. If not as specified,
check the terminal
voltage
of the hold
switch.
OSUOKX-134
03UOKX.135
Inspection
of continuity
1. Disconnect
the connector.
2. Check continuity
between
terminals
E and F.
Inspection
of voltage
1. Remove
the rear console.
2. Turn the ignition
switch ON.
3. Check the voltage
between
terminals
A and B.
Terminal
voltage
Switch
Approx.
12V
Released
Below 1.5V
Depressed
4. If not correct,
go to the next step.
I
/
OBUOKX-13'
03UOKX-13
ENGINE
START
BACK
- UP LIGHTS
ILLUMINATE
I
Continuity
Switch
Yes
No
Released
Depressed
3. If not correct,
replace
the selector
lever knob as an as-
sem bly.
Replacement
1. Remove
the rear console.
2. Disconnect
the connector.
3. Remove
the selector
lever knob.
4. Install a new selector
lever knob.
5. Install the rear console.
INHIBITOR
SWITCH
Inspection
Inspection
of operation
1. Verify that the starter operates
with the ignition
switch at
START
position
and the selector
lever in P and N ranges
only.
2. Verify that the back-up
lights illuminate
when shifted to R
range with the ignition
switch in ON position.
3. Check the inhibitor
switch if not as specified.
03UOKX-138
K2-140