Behaviour when
turning off and on
Behaviour after
power failure
Reference Station
Turning the GRX1200 Series off and on again resets the receiver. The conse-
quences are:
If the configuration of the output is stored in the configuration set, standard
NMEA messages are still output.
All data/message outputs scheduled via OWI or LB 2 commands are no longer
output.
Data logging parameters and interface configuration options, that have been set
by OWI or LB 2 commands and have not been saved to a configuration set using
the corresponding OWI or LB 2 command, are reset.
After temporary power failure, the GRX1200 Series will automatically power itself up
and resume the previously set operations including OWI or LB2 outout. Two power
fail recovery options are available - Sudden Loss Only and Always. To access the
configuration select either:
RX1200: Main Menu: Config...\General Settings...\Start Up & Power Down.
Computer: Configuration - Start Up & Power Down in the web interface.
GPS1200