PPS output
Technical Data
Humidity
Type
All receivers
For GX1200 with PPS/Event option and GRX1200 Pro/GRX1200 GG Pro
PPS output characteristics:
Peak:
Impedance:
Pulse length:
Leading edge:
Positive/negative edge:
Cable connectivity:
Matched with an appropriate impedance of: 50 Ω
Socket:
Protection
Up to 100 %
The effects of condensation are to be effectively counter-
acted by periodically drying out the receiver.
3.3 V = High
50 Ω
1 ms
Coinciding with the beginning of each epoch.
Selectable via RX1200.
GPS1200
LEMO ERN.0S.250.CTL
121