Trouble shooting 27
INDOOR UNIT Error Method:
Communication Error
(Main PCB ---> Display PCB)
Detective Actuators:
Indoor Unit Main PCB Circuit
Display PCB
Forecast of Cause:
1. Connection failure
Check Point 1-1 : Reset the power and operate
Does Error indication show again?
YES
YES
Check Point 2 : Check Connection
Check connection between Main PCB and
Display PCB.
(If there is loose connector or open cable)
OK
Check Point 3 : Replace Display PCB
>> If Check Point 1, 2 do not improve the symptom, change Display PCB.
(If the symptom does not change, replace Main PCB.)
Indicate or Display:
Indicate or Display:
Refer to error code table.
Detective details:
When the Display PCB cannot receive the signal from the Main PCB.
2. External cause
3. Display PCB failure
NO
02-36
4. Main PCB failure
Check Point 1-2:
Check external cause such as noise
Check the complete insulation of the grounding.
Check if there is any equipment that causes harmonic wave
near the power cable (Neon light bulb or any electronic
equipment which causes harmonic wave).