1.3.3 Technical data

The data below only apply to front-mounted burners from Riello
Oil: fuel oil, max. viscosity at 20°C: 6 mm
DESCRIPTION
OIL DATA
Burner model
Burner type
Nozzle (Delavan)
Nominal load (lower value)
Nominal power
Oil flow rate
Pump pressure
GENERAL
Contents
Number of anodes
Number of fire tubes
Cold water inlet
Hot water outlet
Drain valve
Anode
T & P connection
Maximum working pressure
Weight (empty)
2
/s
Unit
SOF 85
SOF 85
220
260
[-]
RG 2
RG 2
[-]
377 T1
377 T1
[-]
1.25x80W
1.5x80B
kW
62.8
75.4
kW
52.3
63.3
kg/h
5.3
bar
12
litre
322
322
-
2
-
6
-
ISO-7 Rp 1½
ISO-7 Rp 1½
-
ISO-7 Rp 1½
ISO-7 Rp 1½
-
¾ - 14 NPT
¾ - 14 NPT
-
¾ - 14 NPT
¾ - 14 NPT
-
1 - 11.5 NPT
1 - 11.5 NPT
bar
8
kg
260
260
SOF 85
SOF 75
300
390
RG 3
RG 3
393 T1
393 T1
1.75x80B
2.25x80B
87.9
113
73.9
95
6.3
7.4
9.5
12
12
12
318
282
2
2
6
7
12
ISO-7 Rp 1½ ISO-7 Rp 1½
ISO-7 Rp 1½ ISO-7 Rp 1½
¾ - 14 NPT
¾ - 14 NPT
¾ - 14 NPT
¾ - 14 NPT
1 - 11.5 NPT
1 - 11.5 NPT
8
8
260
290
SOF 75
SOF 70
470
700
RG 3
RG 4S
393 T1
396 T1
2.75x80B
4.0x80B
138
201
116
168.8
11.6
16.9
12
12
282
259
3
3
4
12
16
ISO-7 Rp 1½
ISO-7 Rp 1½
ISO-7 Rp 1½
ISO-7 Rp 1½
¾ - 14 NPT
¾ - 14 NPT
¾ - 14 NPT
¾ - 14 NPT
1 - 11.5 NPT
1 - 11.5 NPT
8
8
8
290
335