Sanyo VPC-X1420EXR Service Manual page 15

Table of Contents

Advertisement

3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP1
COMPL PWB ST1
COMPL PWB ST2
ASSY, FLEXIBLE PWB CA1
LENS
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
3-13. Firmware uploading procedure. (Page 19)
Refer to
3-8. Adjust Specifications
1. Lens Adjustment (1m)
Camera
Preparation:
POWER switch: ON
Adjustment condition:
Siemens star chart (A3)
Fluorescent light illumination with no flicker
Illumination above the subject should be 700 lux ± 10%.
Lens
Lens
Adjust-
Adjust-
ment
ment
(1m)
(Infinity)
100
0.5 cm
Siemens
star chart
CCD Black
CCD White
Point And
AWB
Point
White Point
Defect
Adjust-
Defect Detect
Detect
ment
Adjustment
Adjustment
In Lighted
Note:
Do not vibrate during the adjustment.
The temperature of the camera should be allowed to reach
room temperature before adjusting the focus. If any slight in-
creases or decreases in room temperature occur, wait until
the temperature of the camera reaches room temperature
before carrying out adjustment.
Adjustment method:
1. Set the siemens star chart 100 ± 0.5 cm from lens surface
(zoom wide position) so that it becomes center of the screen
(zoom wide and tele).
2. Double-click on the DscCalDi.exe.
3. Click the "Focus", and Click the "Yes".
4. Lens adjustment value will appear on the screen.
5. Click the OK.
– 15 –