Timing Specification - Sony GDM-F500R Service Manual

Hide thumbs Also See for GDM-F500R:
Table of Contents

Advertisement

GDM-F500R

TIMING SPECIFICATION

MODE AT PRODUCTION
RESOLUTION
CLOCK
— HORIZONTAL —
H-FREQ
H. TOTAL
H. BLK
H. FP
H. SYNC
H. BP
H. ACTIV
— VERTICAL —
V. FREQ(HZ)
lines
V. TOTAL
V. BLK
V. FP
V. SYNC
V. BP
V. ACTIV
— SYNC —
INT(G)
EXT(H/V)/POLARITY
EXT(CS) /POLARITY
INT/NON INT
MODE 1
MODE 2
640 X 480
1600 X 1200
25.175 MHz
229.500 MHz
31.469 kHz
106.250 kHz
usec
usec
31.778
9.412
6.356
2.440
0.636
0.279
3.813
0.837
1.907
1.325
25.422
6.972
59.940 Hz
85.000 Hz
lines
lines
525
1250
45
50
10
1
2
3
33
46
480
1200
NO
NO
YES N/N
YES P/P
NO
NO
NON INT
NON INT
MODE 3
1920 X 1440
297.000 MHz
112.500 kHz
usec
8.889
2.424
0.485
0.754
1.185
6.465
75.000 Hz
lines
1500
60
1
3
56
1440
NO
YES P/P
NO
NON INT
– 4 –
MODE 4
MODE 5
1800 X 1440
1800 X 1350
299.436 MHz
300.000 MHz
120.740 kHz
120.968 kHz
usec
usec
8.282
8.267
2.271
2.267
0.668
0.480
0.481
0.667
1.122
1.120
6.011
6.000
80.120 Hz
85.009 Hz
lines
1507
1423
67
73
1
1
3
3
63
69
1440
1350
NO
NO
YES P/P
YES P/P
NO
NO
NON INT
NON INT
99.11.09 VER.