Chapter 5 Host Interface Management

5.2 Modify Port Parameters

5.2
Modify Port Parameters
This function sets the parameter for the ETERNUS DX side host interface port.
The settings vary depending on the following port types.

• Modify FC Port Parameters

• Modify iSCSI Port Parameters
• Modify SAS Port Parameters
• Modify FCoE Port Parameters
5.2.1
Modify FC Port Parameters
This function sets the parameters for the FC host interface port that connects between the ETERNUS DX and
the host, or connects between the storage systems for REC or Storage Migration.
When changing port parameters during operation, stop access from the server that is connected to the target
port. Host access does not need to be stopped to change the port parameters of newly added Channel
Adapter (CA) ports.
The procedure to set FC port parameters is as follows:
Procedure
1
Select which FC port to set the parameters for (multiple selections can be made) and click
[Configure FC Port] in [Action].
 The [Modify FC Port Parameters] screen appears.