Use a soft cloth soaked with warm water (lower than 35°C) or neutral detergent (for tableware) to wipe dirt from the surface.
Four casters
Poor insulation or rust may occur if the main unit gets wet.
NOTE
When using chemical agent, please follow the direction for use.
Do not use materials that harm plastics, for example, diluent, gasoline, alcohol, petroleum, soap, lapping
powder, alkaline detergent, hot water and acid.

WHEN NOT USING FOR A LONG PERIOD OF TIME

1
Remove the power plug
2
Empty the water
tank, and leave it
to air dry for
Drain outlet
about two days
3
Clean the air inlet
Air inlet
4
Avoid direct
sunlight and
keep the
dehumidifier at a
place with good
ventilation
18
Wipe the neutral detergent off
with a cloth that is washed with
clean water and wringed out
Do not forget to clean and care
the air inlet, air outlet and four
casters since they are easily
contaminated
Remove the cover of the water
tank, and wipe the inner surface
Vacuum
cleaner
Place the dehumidifier in the
supplied carton or cover it with a
dustproof hood (such as a
plastic bag) for storage
If the dehumidifier is not
covered, dust may enter the
main unit and will be blown out
when the dehumidifier operates
next time
Keep the main unit upright
during storage. Do not lay it
horizontally or invert it

SPECIFICATIONS

Model
Power Supply
30°C/80%RH
Dehumidifying Capacity
26.7°C/60%RH
Power Consumption
26.7°C/60%RH
Standby Status
Dehumidification Area
Water Tank Capacity
Length of Power Cord
Dimensions
Weight
According to standards of Japan Electrical Manufacturers' Association (JEMA).
The dehumidifying capability: the amount of humidity that a dehumidifier removes from the air in a
day when room temperature and relative humidity are kept at 30°C/80%RH and 26.7°C/60%RH
respectively.
Please be well noted that the product specifications are subject to change without a prior notice.
DW-D12A
220V-240V/50Hz
12L/day
6.5L/day
160W
0.45W
13-26m
2
Approx. 4L
Approx. 1.8m
314mm(W)×225mm(D)×527mm(H)
About 10kg