Privacy mask
Privacy Mode
Up
Left
Right
Down
8. Gyro Offset Adjustment
Adjustment location: EIS Adj of computer screen
Measuring location: Computer screen,
Measuring equipment:
Tele
Note: Do not shake the camera while gyro offset is being
Adjustment method:
Wide
1. Connect the camera's USB terminal to the computer'
USB connector.
2. It turns on power while pushing the
SET button of the CA-5 board.
3. Double-click on the DscCalDi.exe.
OK
4. Select "EIS Adj" on the LCD "Test".
5. Gyro offset adjustment value will appear on the screen.
6. Click the OK.
Adjustment value determination is effectuated using the
"Offset" values. If
Offset= H1,V1
The adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
409<=H1<=614, 409<=V1<=614
-
-
14
adjusted. There is no gyro gain adjustment.
button and the