Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
AF_TEMP_AD: ATAD
ATAD: adjustment value of focus temperature A/D
(0<=ATAD<=1023)
AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(-126<=ZW<=110)
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(-138<=ZM1<=121)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(-132<=ZM2<=114)
AF_MID3: ZM3
ZM3: adjustment value of focus at zoom position middle3
(-123<=ZM3<=204)
AF_MID4: ZM4
ZM4: adjustment value of focus at zoom position middle4
(-147<=ZM4<=215)
AF_MID5: ZM5
ZM5: adjustment value of focus at zoom position middle5
(-173<=ZM5<=248)
AF_MID6: ZM6
ZM6: adjustment value of focus at zoom position middle6
(-180<=ZM6<=263)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(-188<=ZT<=274)
4. AWB Adjustment
Camera
Pattern box
-
Adjustment location: AWB of computer screen
Measuring location: Computer screen
Measuring equipment: Pattern box
Preparation:
Adjusting method:
1. It turns on power while pushing the
SET button of the CA-5 board.
2. Set a distance of 0.5-1.0 cm between camera lens and
the pattern box. (Do not enter any light.)
3. Connect the camera's USB terminal to the computer'
USB connector.
4. Double-click on the DscCalDi.exe.
5. Click the AWB, and click the Yes.
6. AWB adjustment value will appear on the screen.
7. Click the OK.
Adjustment value determination is effectuated using the
"AGC", "CHECK", "CHECK_ND", "IRIS_GAIN",
"IRIS_OFFSET", "MS", "MS_M", "MS_C", "MS_C2",
"MS_C3", "IRIS_PWM1", "IRIS_PWM2", "IRIS_PWM3" and
"IRIS_PWM4" values. If
AGC= a1
CHECK= wc0, wc1, wc2
CHECK_ND= wnc0, wnc1, wnc2
IRIS_GAIN= g
IRIS_OFFSET= o
MS= ms1, ms2,
MS_M= ms3, ms4,
MS_C= ms5, ms6,
MS_C2= ms7, ms8,
MS_C3= ms9
IRIS_PWM1= s1, s2
IRIS_PWM2= s3, s4
IRIS_PWM3= s5, s6
IRIS_PWM4= s7
the adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
a1<=2610
wc0=128 ± 2, wc1=128 ± 2, wc2<=255
wnc0=128 ± 2, wnc1=128 ± 2, wnc2<=255
0<=g<=255, 0<=o<=255
3100<=ms1<=4500, 600<=ms2<=2000,
2771<=ms3<=4171, 2044<=ms4<=3444,
1592<=ms5<=2992, 1109<=ms6<=2509,
1000<=ms7<=2400, 829<=ms8<=2229,
676<=ms9<=2076
0<=s1<=255, 0<=s2<=255, 0<=s3<=255, 0<=s4<=255,
0<=s5<=255, 0<=s6<=255, 0<=s7<=255
s1>s2>s3>s4>s5>s6>s7
Adjustment values other than the above are irrelevant.
-