Upgrading The Monitor; Upgrading The Controller - Sony Trimaster PVM-L3200 Operation Manual

Lcd video monitor
Table of Contents

Advertisement

Display example
Confirming the upgrade data of the kernel of
the monitor
Double-click the following file:
MSSONY/MONITOR/PVM_L/UPDATES/KERNEL/PV
M_L3200/checksum_kernel.bat
When the data are saved correctly
E:\MSSONY\MONITOR\PVM_L\UPDATES\KERNEL\PVM_L3200>check_data\\checksum -c check_d
ata\\checksum_table -f vxWorks_rom.bin -f version
*********************************
*
*
*
check 2 files Ok
*
*
*
*
Success
*
*
*
*********************************
E:\MSSONY\MONITOR\PVM_L\UPDATES\KERNEL\PVM_L3200>pause
"Success" is displayed.
When the data are not saved correctly
E:\MSSONY\MONITOR\PVM_L\UPDATES\KERNEL\PVM_L3200>check_data\\checksum -c check_d
ata\\checksum_table -f vxWorks_rom.bin -f version
"vxWorks_rom.bin" check : Error!!!
*********************************
*
*
*
1 file error
*
*
*
*
Error
*
*
*
*********************************
E:\MSSONY\MONITOR\PVM_L\UPDATES\KERNEL\PVM_L3200>pause
"Error" is displayed.

Upgrading the Monitor

1
Insert the "Memory Stick PRO" into the Memory Stick
insertion slot of the controller.
2
Select the Monitor Upgrade menu in the System
Configuration menu (page 71).
3
Enter the 4-digit password.
The Monitor Upgrade screen is displayed, and the
current version is indicated.
For the password, see Password (page 70) of the
System Configuration menu.
94
Upgrading the Monitor and Controller
4
Select the item to upgrade from among Software
Upgrade, Kernel Upgrade, and FPGA Upgrade.
After about 10 seconds, the old and new software
versions or kernel version, and the message to confirm
that you with to execute the upgrade are displayed.
When FPGA Upgrade is selected, the new versions of
FPGA1, FPGA2, FPGA CORE, starting from the left,
and a confirmation message are displayed.
Display example
Monitor software will be upgraded and monitor will
restart.
Are you sure?
5
Confirm the data version and press the ENTER (Ent)
button.
Upgrading starts.
The "In progress x" is displayed and "x" flashes
during upgrading. The "x" indication may stop
flashing during upgrading, but the data are being
upgraded correctly.
It takes about 6 minutes to upgrade the software and
about 1 minute to upgrade the kernel or FPGA data.
Notes
• Do not remove the "Memory Stick PRO" from the
Memory Stick insertion slot during upgrading or
disconnect the LAN cable between the monitor and
controller.
• Do not turn off the power of the monitor and
controller during upgrading.
After completion of upgrading, the display on the
screen disappears, and the system is restarted. After
restarting, the previous screen is displayed.
6
Select the Monitor Upgrade menu in the System
Configuration menu and confirm that the version of the
selected item has been upgraded.
When the upgrade sequence does not move forward
correctly, the message such as "Procedure failure" is
displayed in red. If this error message is displayed, contact
your Sony representative.

Upgrading the Controller

1
Insert the "Memory Stick PRO" into the Memory Stick
insertion slot of the controller.
2
Select the Controller Upgrade menu in the Controller
menu (page 80).
3
Enter the 4-digit password.