GB
TABLE FOR THE CHOICE OF THE INJECTORS
Nominal
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring (TR)
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring (TR)
LUBRICATION OF THE GAS TAPS
If a tap becomes stiff, do not force; contact your local Service Agent.
IMPORTANT
All intervention regarding installation maintenance and conversion of the appli-
ance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
Reduced
Power
Power
[kW]
[kW]
1,00
0,30
1,75
0,45
3,00
0,75
3,50
1,50
G 30 - 28-30 mbar
G 31 - 37 mbar
Ø injector
[1/100 mm]
50
65
85
95
Air necessary for combustion [m
2,00
3,50
6,00
7,00
II
Cat:
2H3+
G 20
20 mbar
Ø injector
[1/100 mm]
72 (X)
97 (Z)
115 (Y)
135 (T)
3
(2 m
/h x kW)
3
/h]
37