CONVERSION TO NATURAL GAS OR TO LPG
INJECTORS REPLACEMENT OF TOP
BURNERS
If the injectors are not supplied they can
be obtained from the "Service Centre".
The diameter is marked on the injector
in cents of millimetre.
Select the injectors to be replaced
according to the "Table for the choice of
the injectors" (page 37).
To replace the injectors:
– Remove the gratings, the burner and
the covers;
– Using a wrench, substitute the nozzle
injectors "J" (Fig. 10.4a - 10.4b) with
those most suitable for the kind of
gas for which it is to be used.
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
ADJUSTING OF THE MINIMUM OF
THE TOP BURNERS
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the fol-
lowing way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a small flat screwdriver turn the
screw inside the tap rod to the correct
regulation (fig. 10.5).
Normally for LPG, tighten up the regula-
tion screw.
36
J
Fig. 10.4a
J
Fig. 10.4b
Fig. 10.5