Display Function

1. Heating Model
Operation Indicator
• Cooling, Soft Dry, Fan, Heating
Sleep Timer Indicator
• Sleep Mode
Timer Indicator
• Timer Mode
Defrost Indicator
• Hot-start, Defrost
PLASMA Indicator
• PLASMA Mode
Telephone control
Indicator
• Telephone Control Mode

Self-diagnosis Function

Error
Code
(Indoor body operation LED)
(once)
1
3sec
PLASMA
Error Display LED
3sec
3sec
2. Cooling Model
Operation Indicator
• Cooling, Soft Dry, Fan
Sleep Timer Indicator
• Sleep Mode
Timer Indicator
• Timer Mode
Compressor on Indicator
PLASMA Indicator
• PLASMA Mode
Telephone control
Indicator
• Telephone Control Mode
Error contents
• Indoor room temperature
thermistor open/short
• Indoor pipe temperature
thermistor open/short.
-20-
OUTDOOR
PLASMA
SVC check point
• Indoor Thermistor
assembly check