Sensitivity Set Up - Carson SPY HAWK Basic Instruction Manual

Radio controlled plane rtf
Table of Contents

Advertisement

Available languages

Available languages

4. Expert Mode reverse setup
Hold down the Elevator/Aileron or (mode 1 : Elevator/Rudder)
stick for 1 second to enter the setting status, press Throttle
Trim key up or down to choose reverse, and then hold down the
Elevator/Aileron or (mode 1: Elevator/Rudder) stick for 1 second to
confirm and exit. This increases the rudder deflection.
g. Sensitivity set up
1. Rudder ensitivity setup NOR (normal) mode
Hold down the Elevator/Aileron or (mode 1: Elevator/Rudder) stick for
1 second to enter the setting status, press Throttle/Rudder or (mode
1: Elevator/Rudder) key until the three-point dotted line symbol start
to flash (see picture below), press Rudder Trim to idea sensitivity and
then hold down the Elevator/Aileron or (mode 1: Elevator/Rudder)
stick for 1 second to confirm and exit.
2. Elevator sensitivity setup – NOR (normal) mode
Hold down the Elevator/Aileron or (mode 1: Elevator/Rudder) stick for
1 second to enter the setting status, press Throttle/Rudder or (mode 1:
Elevator/Rudder) key until the three-point dotted line symbol start to
flash (see picture below), press Elevator Trim to idea sensitivity and then
hold down the Elevator/Aileron or (mode 1: Elevator/Rudder) stick for 1
second to confirm and exit.
3. Aileron sensitivity setup – NOR (normal)
modeE (3CH exception)
Hold down the Elevator/Aileron or (mode 1: ElevatorlRudder) stick for
1 second to enter the setting status, press Throttle/Rudder or (mode 1:
Elevator/Rudder) key until the three-point dotted line symbol start to
flash (see picture below), press Aileron Trim to idea sensitivity and then
hold down the Elevator/Aileron or (mode 1 : Elevator/Rudder) stick for 1
second to confirm and exit.
4. Tail rotor (rudder) sensitivity – Expert mode
Hold down the Elevator/Aileron or (mode 1: Elevator/Rudder) stick for 1
second to enter the setting status, press Throttle/Rudder or (mode 1:
Elevator/Rudder) key until the five-point dotted line symbol start to
flash (see picture below), press Rudder Trim to idea sensitivity and then
hold down the Elevator/Aileron or (mode 1: Elevator/Rudder) stick for 1
second to confirm and exil.
T
X
M1
Flashing
Flashing
CARSON Spy Hawk • 50 050 5019 + 20 + 21 + 22
M2
Expert
GB
Flashing
Flashing
45

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Spy hawk basic autoSpy hawk5.9gh2 fpv

Table of Contents