ASU15RLS / AOU15RLS
INDOOR UNIT
1 2 3 4 5 6 7 8
CN201
CN8
RED
1
1
1
WHITE
2
2
2
INDICATOR
WHITE
3
3
3
WHITE
PCB ASSY
4
4
4
CN3
WHITE
5
5
5
WHITE
6
6
6
WHITE
7
7
7
CONTROLLER
PCB ASSY
BLUE
1
1
YELLOW
2
2
WHITE
3
3
CN7
BLACK
FAN MOTOR
F M
4
4
5
5
RED
6
6
CN1
1 2 3 4 5
1 2 3 4 5
THERMAL
FUSE 102
TERMINAL
2010.08.26
RED
1
1
ORANGE
2
2
YELLOW
M
LOUVER
CN5
3
3
PINK
4
4
BLUE
5
5
BLACK
1
1
THERMISTOR
BLACK
( PIPE TEMP. )
2
2
CN4
BLACK
3
3
THERMISTOR
BLACK
4
4
( ROOM TEMP. )
1
2
TEST
CN6
3
4
5
W4
G
EARTH TERMINAL
1 2 3
OUTDOOR UNIT
REACTOR
or
WHITE
RED
THERMISTOR ( PIPE TEMP. )
THERMISTOR
( DISCHARGE TEMP. )
THERMISTOR ( OUTDOOR TEMP. )
WHITE
FUSE 250V 5A
FUSE
250V 20A
TERMINAL
1
2
3 L1 L2 G
POWER SOURCE
9
CONTROLLER PCB ASSY
W7
W8
W9
WHITE
W10
RED
W11
1
1
2
2
3
3
4
4
CN800
5
5
BLACK
1
1
6
6
BLACK
2
2
7
7
CN71
BROWN
3
3
BROWN
4
4
1
1
2
2
3
3
CN40
4
4
5
5
6
6
BLACK
1
1
2
2
CN70
BLACK
3
3
RED
W4
WHITE
W2
BLACK
W1
1
1
W3
CN30
2
2
3
3
R
RED
S
WHITE
COMPRESSOR
CM
BLACK
C
RED
BLACK
FM
FAN MOTOR
WHITE
YELLOW
BROWN
RED
BLUE
ELECTRIC
PMV
ORANGE
YELLOW
EXPANSION VALVE
WHITE
BLACK
4-WAY VALVE
4WV
BLACK

Hide quick links: