5.6.3 Auto-white balance

If the reference color temperatures do not match your lighting conditions carry out the auto-
white procedure as follows:
1.
Use the Color temperature switch to select one of the memory positions FL50, FL60,
AW1 or AW2 in which to store the measured color temperature value.
2.
Press once on the White balance switch at the front of the camera to start the automatic
white balance procedure. The following appears in the viewfinder:
-
3.2
Note
Note
If you did not select one of the memory positions FL50, FL60, AW1 or AW2, the 'Precondition
fail' message appears in the viewfinder.
3.
Point the camera so that the reference white surface is between the two small black
boxes.
4.
Press the White balance switch again to start the measurement procedure. A message
indicating that the process is runnning appears.
-
3.2
LDK 3000+ High-Definition Camera Head User's Guide (v1.0)
SW1
SW 2
Std
File
+
+
Color temperature
selection switch
+
++
REC
MED IA
BAT T
ND/RE
FOC+
AWHITE: window
4.7
5.6
7.5
FL
AW1
AW2
!
++
REC
MED IA
FOC+
+
BAT T
ND/RE
AWHITE: running
4.7
5.6
7.5
FL
AW1
AW2
!
Chapter 5 - Video setup
V
Exp.
White
Clean
VTR start
shift
Time
Bal.
scan
Select
Audio Level
Auto white balance
switch