Self Diagnosis Function - Sony KF-50SX100K Service Manual

Sony kf-50sx100 lcd projection tv service manual
Hide thumbs Also See for KF-50SX100K:
Table of Contents

Advertisement

1-1. LE-3 SELF DIAGNOSTIC SOFTWARE
The identification of errors within the LE-3 chassis is triggered in one of two ways : - 1: Busy or 2: Device failure to respond to IIC. In
the event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with
continuous flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be
faulty the relevant device number will be displayed through the LED (Series of flashes which must be counted) See table 1., non fatal
errors are reported using this method.
Diagnostic Item
No. of times Standby
Description
Power does not turn on
SET 5V Dowin
No error
Not allowed (may be confused with Sircs response flash)
SET 5V Down
Lamp Cover error
Fan error
Lamp Driver error
Not used
Speaker Protection
General IIC Line 0 error
MEGATEXT (IC9502)
NVM (IC9108)
Main colour decoder (IC8301)
MCP (IC701)
Multi sound processor (IC4702)
Auto Wide (IC8700)
External RAM (IC9107)
Lamp error
Flash Timing Example : e.g. error number 3
Standby LED
ON

SELF DIAGNOSIS FUNCTION

Probable cause Location
LED Flashes
Power cord is not plugged in
Does not light
Fuse is Burned out
Q1606, 1607 Power FET is shorted
2 times
ERROR
ON
OFF
OFF
KF-50SX100/50SX100K/50SX100U
Power does not come on
No power is supplied to the TV
AC power supply is faulty
Power does not come on
(G Board) Load on power line has shorted
STBY LED ERROR COUNT
00
01
02
03
04
05
06
07
08
09
10
11
14
15
16
17
Lamp LED continnously on
ON
– 3 –
RM-903
RM-903
Detected Symptoms
RM-903

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kf-50sx100uKf-50sx100

Table of Contents