Conditions
[General]
SMDR Format
The following SMDR format parameters can be set through system programming in order to match the
paper size being used by the printer:
a.
Page Length: determines the number of lines per page.
® 13.1 [11-1] Main—SMDR—
® [802] SMDR Page Length
b.
Skip Perforation: determines the number of lines to be skipped at the end of every page.
® 13.1 [11-1] Main—SMDR—
® [803] SMDR Skip Perforation
The page length should be at least four lines longer than the skip perforation length.
Explanation:
Skip
Perforation
SMDR data is not deleted even if the PBX is reset.
If the PBX is reset during a conversation, the call will not be logged by SMDR.
When a call is made from an extension to a number in the Emergency Dial Table (® 5.1.2 Emergency
Call), the PBX can be programmed to record the call information on SMDR both immediately after the
number is dialed and after the call ends. (Normally, the PBX records the call information only after the call
ends.)
13.1 [11-1] Main—SMDR Options—
The following calls are regarded as two separated calls in the SMDR:
Calls before and after the flash/recall/EFA signal is manually sent during a conversation
CO-to-CO line calls by Call Transfer, FWD or DISA (each is logged as both an "incoming call" and an
"outgoing call")
The PBX waits for a preprogrammed time period after the end of dialing before starting the SMDR timer
for outgoing CO line calls. When the PBX has sent out all dialed digits to the telephone company and this
timer expires, the PBX begins measuring the duration of the call. A display proprietary telephone (PT)
shows the elapsed time of the call. The starting time and the total duration of the call are logged by SMDR.
® 4.5 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—
® [208] Call Duration Count Starting Time for LCOT
Serial Interface (RS-232C) Parameters
The following communication parameters can be assigned for the Serial Interface (RS-232C port).
a.
New Line Code: Select the code appropriate for the PC or printer. If the PC or printer automatically
feeds lines with carriage return, select "CR." If not, select "CR+LF."
® 13.1 [11-1] Main—RS-232C—
® [800] RS-232C Parameter—New Line Code
b.
Baud Rate: Baud rate indicates the transmission speed of data from the PBX to the PC or printer.
® 13.1 [11-1] Main—RS-232C—
® [800] RS-232C Parameter—Baud Rate
Document Version 2013-05
SMDR Format—Page Length (Number of Lines)
SMDR Format—Blank Footer Length (Number of Lines)
Page
Length
Machine
Perforation
Emergency Call Notification
Communication—NL Code
Communication—Baud Rate
16.1.4 SMDR (Station Message Detail Recording)
Dial—Analog CO Call Duration Start
Feature Manual
317