Panasonic KX-NCP500 Feature Manual page 258

Pure ip-pbx
Hide thumbs Also See for KX-NCP500:
Table of Contents

Advertisement

13.1.15 PRIVATE NETWORK FEATURES
Conditions
A CO line which is used for a private network should be assigned "Private" as the networking type. (®
9.1.10 INCOMING CALL FEATURES)
To establish a QSIG network (® 13.1.20 PRIVATE NETWORK FEATURES—QSIG), each ISDN (QSIG)
connection in a TIE line network must have the port on one PBX assigned as a master port, and the port
on the other PBX assigned as a slave port. PBXs that support this feature are KX-NCP series, KX-TDE
series, and KX-TDA series PBXs.
[TIE Line Network Connection Example]
Extn.1000
:
Extn.1999
When a TIE line call arrives at a busy extension which has disabled Call Waiting, the caller will hear a busy
tone. If required, Intercept Routing can be activated.
The Inter-digit time can be assigned for TIE line calls.
® 4.5 [2-3] Timers & Counters—Miscellaneous—
PC Programming Manual References
3.11 [1-1] Slot—Shelf Property - Virtual IP Gateway—GW Settings
3.12 [1-1] Slot—Shelf Property - Virtual IP Gateway—DN2IP
3.33 [1-1] Slot—Port Property - PRI Port—Network Numbering Plan—
3.36 [1-1] Slot—Port Property - T1 Port—
4.5 [2-3] Timers & Counters—Miscellaneous—
4.9 [2-6-1] Numbering Plan—Main—Features
Idle Line Access (Local Access)
Trunk Group Access
TIE Line Access
4.9 [2-6-1] Numbering Plan—Main—Other PBX Extension
4.12 [2-7-1] Class of Service—COS Settings—TRS—
4.18 [2-9] System Options—Option 4—
Required)
5.1 [3-1-1] Trunk Group—TRG Settings—Main—
11.1 [9-1] TIE Table
12.2 [10-2] DIL Table & Port Settings
→DIL—
Trunk Property
→DIL—
DIL Destination—Day, Lunch, Break, Night
→DID/TIE
12.3 [10-3] DID Table—
12.6 [10-4] Miscellaneous—
programmed.)
258
Feature Manual
PBX-1
(A) Master
QSIG Network
(B) Master
(B) Slave
PBX-3
Trunk Property
Incoming Call Inter-digit Timer—DID
Private Network—TIE Call by Extension Numbering (Activation Key
DID Destination—Day, Lunch, Break, Night
Intercept—Routing to Operator - No Destination (Destination is not
PBX-2
(A) Slave
(C) Slave
(C) Master
Extn. 3000
:
Extn. 3999
Incoming Call Inter-digit Timer—DID
Trunk Property
TRS Level—Day, Lunch, Break, Night
COS
Extn. 2000
:
Extn. 2999
Document Version 2013-05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-ncp1000Kx-tde100Kx-tde600Kx-tde200