To end test operation, press the remote controller START/STOP button.
(When the air conditioner is running by pressing the test run button, the OPERATION
Lamp and TIMER Lamp will simultaneously ash slowly.)
[Using the wired remote control] (Option)
For the operation method, refer to the operating manual.
(1) Stop the air conditioner operation.
(2) Press the master control button and the fan control button simultaneously for 2
seconds or more to start the test run.
(3) Press the start/stop button to stop the test run.

11. REMOTE CONTROLLER INSTALLATION

Check that the indoor unit correctly receives the signal from the remote controller,
then install the remote controller holder.
Select the remote controller holder selection site by paying careful attention to the fol-
lowing:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.
11.1. Remote controller holder installation
Install the remote controller a maximum distance of 7 m from the remote control re-
ceiver. However, when installing the remote controller, check that it operates correctly.
Install the remote controller holder to a wall, pillar, etc. with the tapping screw.
remote controller
holder xing
Remote
controller holder
Tapping screw
(small)
12.OPTIONAL KIT INSTALLATION (OPTION)
This air conditioner can be connected with the following optional kits.
• Wired remote controller
• Simple remote controller
• External connect kit
NOTE:
Optional communication kit is required when connecting a wired remote controller or us-
ing the External Input/Output kit. See the communication kit for installation and operation
instructions.
13.FUNCTION SETTING
Perform the "FUNCTION SETTING" according to the installation conditions using the remote
controller.
Con rm whether the wiring work for Outdoor unit has been nished.
Con rm that the cover for the electrical enclosure on the outdoor unit is in place.
Test run display
CAUTION
remote controller
mounting
1 Set
2 Push
Remote
controller
CAUTION
• This procedure changes to the function settings used to control the indoor unit according
to the installation conditions. Incorrect settings can cause the indoor unit to malfunction.
• After the power is turned on, perform the "FUNCTION SETTING" according to the
installation conditions using the remote controller.
• The settings may be selected between the following two: Function Number or Setting
Value.
• Settings will not be changed if invalid numbers or setting values are selected.
• Refer to the installation manual enclosed with the remote control unit when the wired
remote control unit (option ) is used.
Entering the Function Setting Mode
While pressing the POWERFUL button and SET TEMP. (
button to enter the function setting mode.
STEP 1
Selecting the Remote Controller Signal Code
Use the following steps to select the signal code of the remote con-
troller. (Note that the air conditioner cannot receive a signal code if
the air conditioner has not been set for the signal code.)
The signal codes that are set through this process are applicable
only to the signals in the FUNCTION SETTING. For details on how
to set the signal codes through the normal process, refer to Remote
controller signal code.
(1) Press SET TEMP. (
/
) button to change the signal
code between
. Match the code on the
display to the air conditioner signal code. (initially set to
) (If the signal code does not need to be selected, press
the 10°C HEAT button and proceed to STEP 2.)
(2) Press the MODE button and check that the indoor unit can
receive signals at the displayed signal code.
(3) Press the 10°C HEAT button to accept the signal code,
and proceed to STEP 2.
The air conditioner signal code is set to A prior to shipment. Contact your retailer to
change the signal code.
The remote controller resets to signal code A when the batteries in the remote control-
ler are replaced. If you use a signal code other than signal code A, reset the signal
code after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the signal codes
(
) until you nd the code which operates the air conditioner.
STEP 2
Selecting the Function Number and Setting Value
(1) Press the SET TEMP. (
/
) buttons to select the function number. (Press the 10°C
HEAT button to switch between the left and right digits.)
(2) Press the POWERFUL button to proceed to setting the
value. (Press the POWERFUL button again to return
to the function number selection.)
(3) Press the SET TEMP. (
/
) buttons to select the
setting value. (Press the 10°C HEAT button to switch
between the left and right digits.)
(4) Press the MODE button, and START/STOP button, in
the order listed to con rm the settings.
(5) Press the RESET button to cancel the function set-
ting mode.
(6) After completing the FUNCTION SETTING, be sure
to turn off the power and turn it on again.
After turning off the power, wait 10 seconds or more before turning on it again.
The Function Setting does not become active unless the power is turned off then on
again.
) simultaneously, press the RESET
Function number
CAUTION
Setting
value
En-8