Led Test And Continuity Threshold; Input Characteristics - Fluke 15B+ User Manual

Digital multimeters
Hide thumbs Also See for 15B+:
Table of Contents

Advertisement

LED Test and Continuity Threshold

Function
[1]
LED V
Test
(LED Test Socket)
F
[2]
LED V
Test
(Test Leads)
F
Continuity Threshold
Open circuit test voltage is ±12 V and short-circuit current is <±5 mA (typical).
[1]
Open circuit test voltage is ±12 V and short-circuit current is <±3 mA (typical).
[2]
measurement with driving current under 2.2 ±0.4 mA.
[3]
V
F

Input Characteristics

Function
AC Volts
AC Millivolts
DC Volts
DC Millivolts
6
[1]
10
V Hz Max
Lighting Range
Measurement Range
1.00 to 6.00 V
1.00 to 6.00 V
NA
Overload
Input Impedance
Protection
(Nominal)
[1]
1000 V
>10 MΩ, <100 pF
400 mV
>1MΩ, <100pF
[1]
1000 V
>10 MΩ, <100 pF
400 mV
>1MΩ, <100pF
Resolution
NA
1.00 to 6.00 V
0.01 V
NA
Common Mode
Rejection Ratio
>60 dB at dc,
50 Hz or 60 Hz
>80 dB at dc,
50 Hz or 60 Hz
>100 dB at dc,
50 Hz or 60 Hz
>80 dB at dc,
50 Hz or 60 Hz
Digital Multimeters
Accuracy Specifications
Accuracy
NA
NA
[3]
10 %
Ω
NA
70
Normal Mode
Rejection Ratio
_
_
>60 dB at
50 Hz or 60 Hz
_
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

17b+18b+

Table of Contents