VF connector
Detaching the viewfinder
You can carry out this by following the attaching
procedure in reverse order, but there is an
additional action to take: when detaching the
viewfinder from the fitting shoe, pull up the
stopper.

Adjusting the viewfinder position

To adjust the viewfinder left-right position,
loosen the left-right positioning ring, and to adjust
the front-back position, loosen the front-to-back
positioning knob.
Viewfinder left-to-right positioning ring
Viewfinder front-to-back positioning knob
Note
When the viewfinder is attached, do not leave the
camcorder with the eyepiece facing the sun. Direct
sunlight can enter through the eyepiece, be focused in the
viewfinder and cause fire.

Moving the viewfinder shoe up

1
Using a hexagonal wrench 2.5 mm
across flats, remove the bolts (M3×25)
and spring washers, to detach the
viewfinder shoe from the camcorder
body.
Viewfinder shoe assembly
(A-8278-412-G)
2
Fit two of the four holes in the back of
the viewfinder shoe over the upper two
pins on the fixing plate. Make sure that
the triangular mark on the viewfinder
shoe is pointing up.
Pins
Fit these holes
over the pins.
Triangular mark
3
Using the bolts and spring washers
removed in step 1, fix the viewfinder
shoe to the camcorder.