REMOVING THE MAIN CONTROL BOARD ASSEMBLY

Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the refrigerator or disconnect the
power.
2.
Pull the refrigerator out of its mounting
location.
3.
At the rear of the unit, remove the hex-
head screws from the unit compartment
cover and remove the cover.
Main Control
Board Assembly
4.
Remove the inverter assembly (see page
4-17 for the procedure).
5.
Disconnect the 3-, 9-, and 12-pin connec-
tors, as shown below.
6.
Remove the hex-head screw from the
green ground wire.
Screws
Ground Wire
Main Control Board Assembly
7.
Remove the two hex-head mounting
screws from the main control board enclo-
sure and remove it from the unit.
8.
Disconnect the six connectors from the
main control board.
Two Connectors
4-18
3-, 9-, & 12 Pin Connectors
Four Connectors