Initialization Of D, E, F, 7 Page Data; Modification Of D, E, F, 7 Page Data - Sony Handycam Vision CCD-TRV107E Service Manual

Hi8 video camera recorder
Hide thumbs Also See for Handycam Vision CCD-TRV107E:
Table of Contents

Advertisement

CCD-TRV107E/TRV108E/TRV208E/TRV408E
1-2.

INITIALIZATION OF D, E, F, 7 PAGE DATA

1. Initializing the D, E, F, 7 Page Data
Note1: If "Initializing the D, E, F, 7 Page Data" is performed, all
data of the D page, E page, F page and 7 page will be
initialized. (It is impossible to initialize a single page.)
Note2: If the D, E, F, 7 page data has been initialized, "Modification of D,
E, F, 7 Page Data" and all adjustments need to be performed again.
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
Order Page Address Data
1
0
01
2
6
00
3
6
01
4
6
02
5
2
00
6
2
01
7

2. Modification of D, E, F, 7 Page Data

If the D, E, F, 7 page data has been initialized, change the data of
the "Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
D
10 to 7F
F
10 to FF
E
00 to FF
7
00 to 6B
Procedure
01
Set the data.
51
Set the data.
51
Set the data, and press PAUSE
button.
Check that the data changes to
"01".
29
Set the data
29
Set the data, and press the PAUSE
button.
Perform "Modification of D, E, F,
7 Page Data".
Processing after Completing Modification of D, E, F, 7 Page
data
Order Page Address Data
1
2
00
2
2
01
Note: If the following symptoms occur after completing of the
"Modification of D, E, F, 7 page data", check that the data of the
"Fixed data-2" addresses of D page are same as those of the same
model of the same destination.
1) The self-diagnosis code "E:20:00" on the LCD or viewfinder
screen is flashing.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing the D, E, F,
7 Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of D, E, F,
7 Page Data".)
Address
Initial data
00 to 0F
10
00
11 to 12
13
14 to 19
1A
1B to 21
22
23 to 26
27
28 to 33
34
35
36
37
38
39
3A to 3B
3C
3D
3E to 40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
5-8
Procedure
29
Set the data
29
Set the data, and press the PAUSE
button.
Remark
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents