Culligan 9" Owner's Manual page 42

High efficiency twin automatic water softeners
Table of Contents

Advertisement

01023052
42
Standard Manual Regeneration
Function
Screen Display
Button
softening
dec-00-00 12:34A
1)informAtion
>2)mAnuAl mode
mAnuAl mode
>regen now
mAnuAl bypAss
>off
1)informAtion
>2)mAnuAl mode
Range
Changing the Setting
N/A
This is the HOME SCREEN. Press any but-
ton except the CANCEL (X) button to ad-
vance to the MAIN MENU SCREEN.
1–6
Press the DOWN ARROW button to 2)
MANUAL MODE. The screen displays the
Manual Mode settings.
Press the CHECK MARK button and the UP
Regen Off
ARROW or DOWN ARROW button to
change the setting.
Regen
Now
REGEN NOW is the default. Press the
CHECK MARK button to select this option
Regen
to begin regeneration immediately.
Tonite
REGEN OFF specifies that the softener will
Bypass
not regenerate.
REGEN TONITE specifies that the softener
will regenerate that night at 2:00 a.m. (or
at the preset regeneration time). The screen
displays two status messages: SOFTENING
and REGEN TONITE.
BYPASS specifies a preset time when the
softener will be bypassed. Press the CHECK
MARK button to select the total time the soft-
ener is to be in the bypass state.
Press the CHECK MARK button and the UP
Off
ARROW or DOWN ARROW button to se-
30 (min)
lect the total time the softener is to be in the
60
bypass state.
90
120
Press the CHECK MARK button to accept
180
this setting. The screen displays the Manual
Manual
Mode menu.
Bypass
Press the CANCEL/X button until the screen
displays the HOME SCREEN and saves the
settings.