Fill The Salt Storage Container
Fill the salt storage container with water until the level reaches about one (1) inch above the salt
support plate. Pour salt into the container. Fill with salt to within a few inches of the top.
Brine Valve "A" Dimension
The brine valve contains a brine float which can serve as a backup refill shutoff in the event of a
failure, such as a power outage when in the refill position. The float level should be set based on the
salt dosage setting. Refer to Figure 18.
1.
Remove nut retaining brine valve to brine chamber.
2.
Lift the brine valve from the brine chamber.
3.
Find the correct A dimension from 01023053 "Appendix A, Softener Capacities" Table 5.
4.
Set the distance from the top of the filter screen to the base of the float accordingly. The
slight difference in height when the float is pulled up or down is negligible.
5.
Re-install into brine chamber and replace nut.
Figure 18.
Brine valve "A" dimension.
01023052
25