KP-53HS10/61HS10
RM-Y902
RM-Y902
2-15. PICTURE TUBE REMOVAL
CAUTION: Removing the arrow-marked
screws is strictly prohibited.
If removed, it may cause liquid spill.
2-16. HIGH-VOLTAGE CABLE INSTALLATION AND REMOVAL
Lens
Picture tube
2 Four screws
(Tapping head
screw 4x20)
3
(1) Removal
1 Rubber cap
2 HV cable
turn 90°
– 40 –
4 Four screws
(+BVTP 4x20)
5 Lens
9 Four screws
(+BVTP 4x20)
!º Picture tube
8 Diflection yoke
7 Neck assy
6 CR board
1 Four screws
(Tapping head
screw 4x20)
(2) Installation
1 HV cable
Hook
Gutter