Hose #6
Hose #11
Hose #5
1. Remove the clamps from the two drain tubes on the trap.
2. Remove the two screws holding the drain trap to the
blower deck.
3. Remove the trap and hoses from the blower deck .
4. Remove the two plugs from the left side of the cabinet
and install them in the blower deck.
5. (Draining the Vent Elbow) Locate hose #6. Measuring
from the non-grommet end; cut off and discard 1 ½" for
a "D" width cabinet, 5" for a "C" width cabinet, 8 ½"
for a "B" width cabinet.
6. Remove the rubber plug from vent – drain elbow side
port. Place hose #6 on the vent – drain elbow side port
and secure with a silver clamp .
7. Place cap on vent – drain elbow barb fitting and secure
with red clamp
8. Locate hose #5 and cut 3" from the non-grommet end.
Discard the section without the grommet.
9. Insert the cut end of tube #5 through the lower cabinet
drain hole.
10. Connect hose #6 & hose #5 using 100º elbow and secure
with two red clamps
11. (Draining the Collector Box) Install the non-grommet end
of hose #11 from outside the cabinet in the bottom drain
hole. Install on collector box and secure with a silver
clamp.
12. Use two silver clamps and secure the hoses to drain trap.
The trap outlet faces the front of the furnace. Secure
the trap to the cabinet using two screws removed in
step 2 by inserting the two screws through the large set
of holes in the top mounting tabs of the trap into the
two predrilled holes in the side of the cabinet.
13. Place cap on vent – drain elbow barb fitting and secure
with red clamp.
14. Refer to Field Supplied Drain section for instructions on
field supplied / installed drain on outlet of furnace trap.
Figure 24
U
M
I
PFLOW
ODEL
NSTALLED
D
- A
OWN

LTERNATE

Insert flange. Cut 2 ½" long.
R 000142
F
1. Install radius end of hose #5 on RF000142 coupling
and secure with red clamp.
2. Insert coupling in hose #5.
3. Locate another hose #5 and cut 3" from the non-
grommet end. Discard the section without the
grommet.
4. Insert the cut end of tube #5 through the lower cabinet
drain hole.
5. Insert 100 degree elbow in the cut end of hose #5.
6. Locate hose #6. Connect between the coupling and
100 degree elbow, cutting off excess tubing.
C
M
I
OUNTERFLOW
ODEL
NSTALLED
Hose #5 x 2
H
W
L
ORIZONTALLY
ITH
Figure 25
V
ERTICALLY
Hose #4 x 2
Figure 26
S
EFT
IDE