Outdoor noise filter circuit board

PUHZ-RP35VHA2
PUHZ-RP50VHA2
LI, NI
Voltage of 220-240V AC is input.
(Connect to the terminal block(TB1))
CNAC1, CNAC2
220-240V AC
(Connect to the
outdoor controller
circuit board
(CNAC))
EI
Connect to the earth
CN52C
52C relay signal
(Connect to the
outdoor controller
circuit board
(CN52C))
78
CN5
Primary current
(Connect to the
outdoor power
circuit board
(CN5))
LO, NO
Voltage of
220-240V AC is
output.
(Connect to the ACL)