Installation And Interface; Unpacking And Inspection; Interface - Siemens Microfloppy FDD100-5 Operating And Maintenance Manual

Table of Contents

Advertisement

SECTION 2
INSTALLATION AND INTERFACE
2.1
UI\IPACKING AND INSPECTION
During unpacking and inspection, use the following procedure:
A.
Remove contents of shipping container and inspect for in-transit
damage. If damage is evident, notify carrier and manufacturer.
Specify nature and extent of damage.
B.
Verify that contents of shipping container agree with shipping
list. Notify a Company representative if anything is missing.
C.
Verify that model designation and serial number agree with those
on shipping invoice.
D.
Inspect assemblies for loose hardware and connectors; if
necessary, tighten hardware.
2.2
II\lSTALLATION
The Model FDD100-5 Disk Drive may be mounted in one of the following positions:
A.
Horizontally, with PWB facing up as shown in Figure 2-1.
B.
Vertically, on either the right or left side, with the door
opening to one side or the other side.
C.
Vertically, with the door opening upward.
D.
Any combination of A, B, and/or C.
Figure 2-2 shows outline and mounting dimensions.
2.3
INTERFACE
Communication between the Model FDD 100-5 Disk Drive and the controller is established through
an I/O cable. Power to the Model FDD100-5 Disk Drive is applied through a separate cable. Input
interface signal lines are terminated by a resistor network that offers an impedance of 132 Ohms. For
ideal signal transmission, the input/output (I/O) cable should have a characteristic impedance of
132 Ohms. Maximum cable length between the controller and the last disk drive should be not
greater than 10 feet (3.048 m).