LG GSA-4120B Service Manual page 64

Super multi dvd drive
Hide thumbs Also See for GSA-4120B:
Table of Contents

Advertisement

IC601 (M63041AFP) : SPINDLE MOTOR AND 6CH ACTUATOR DRIVER
Block Diagram
M
For SPINDLE
7-13.2V
VM1
GND
SWICHING
Commutation
commutation
STTH
STARTER
CLK
Pin Function
No Pin name Function
1
SPIN
Spindle control voltage input
2
SL1IN
Slide control voltage input1
3
SL2IN
Slide control voltage input2
4
SPLIM
Input terminal for spindle current limit
5
VM2
Motor Power Supply 2(for Slide)
6
SL2+
Slide non-inverted output2
7
GND
GND
8
SL2-
Slide inverted output2
9
SL1+
Slide non-inverted output1
10
SL1-
Slide inverted outptut1
11
GND
GND
12
U
Motor drive output U
13
V
Motor drive output V
14
W
Motor drive output W
15 ACTFLG Pickup protect flag output
16
OPOUT Operational amplifier output
17
OPIN-
Operational amplifier inverted input *
18
SLLIM
Input terminal for slide current limit
19
FG
Frequency generator output
20
EN1
Input terminal for enable 1
21
EN2
Input terminal for enable 2
*1) Please connect 17terninal (OPIN-) to GND, when the OPamp is not used.
*2) Please connect 25terminal(ACTRST) to 5VCC, When the Pick-up protection circuit is not used.
67
Current gain
3A/V
PWM
CIRCUIT
Frequency
150KHz
TSD
FG(x3)
Reverse detect
6.4MHz
7-13.2V
For SLIDE
For/FO/TR/TILT
4.5-5.5V
Voltage gain
Voltage gain
X12
X12
Current gain
0.44[0.88]A/V
CTL
CTL
Frequncy
75KHz
PWM
CIRCUIT
No
Pin name Function
42
REF
41
LOIN
40
FOIN
39
TOIN
38
TLIN
37
TL-
36
TL+
35
FO-
34
FO+
33
GND
32
5VCC
31
TO+
30
TO-
29
GND
28
LO-
27
LO+
26
VM3
1
25 ACTRST*
24
STTH
23
SLGS
22
VM1
For LOADING
4.5-5.5V
7-13.2V
Voltage gain
X12
Current gain
0.44[0.88]A/V
Frequncy
75KHz
PWM
CIRCUIT
Reference voltage input
Loading control input
Focus control voltage input
Tracking control voltage input
Tilt control voltage input
Tilt inverted output
Tilt non-inverted output
Focus inverted output
Focus non-inverted output
GND
5V Power Supply (for FS,TS,TL)
Tracking non-inverted output
Tracking inverted output
GND
Loading inverted outptut
Loading non-inverted output
Power Supply3(for Loading)
2
Pickup protect Reset *
Reference voltage for spindle start up
Input terminal for gain select SL
Motor Power Supply 1(for Spindle)
M
H Bridge
OPOUT
OPIN-
SLGS
Gain Select(SL)
EN2
DSP
ENABLE
EN1
DSP
2

Advertisement

Table of Contents
loading