2A3/4
3-3-10 Feedshift and duplex section
( 1 ) Detaching and refitting the duplex forwarding pulley
Replace the duplex forwarding pulley as follows.
<Procedure>
1. Open the duplex unit.
2. Remove the stop ring and duplex forwarding pulley.
3. Refit all removed parts.
∗ When fitting the duplex forwarding pulley, align the projections of the duplex
forwarding pulley with the slots in the forwarding pulley.
3-3-80
Forwarding pulley
Slots
Stop ring
Figure 3-3-94
Duplex forwarding
pulley
Projections