Danfoss HC8000 Series User Instructions
Danfoss HC8000 Series User Instructions

Danfoss HC8000 Series User Instructions

Electronic programable room thermostats

Advertisement

Quick Links

User Instructions

Electronic Programable Room Thermostats
HC8000 Series Heat/Cool & HP8000 Heat Pump Thermostats
Product Features
7-day, 5/2-day or 24 hour programing, set by installer
2, 4 or 6 programed events each day, set by installer (can
also be set up as regular non-programable thermostat)
AM/PM or 24 hour clock display set by user
Fahrenheit or Centigrade temperature display, set by user
Easy to use Daylight saving time change, set by user
Electronic memory for retention of settings
Factory preset programs which can be edited by user
Available in battery and 24 Volt versions
Available in heat / cool versions, 1 heat / 1 cool & 2 heat /
2 cool models
Available in heat-pump versions, 2 heat / 1 cool & 3 heat /
2 cool models, each with emergency heat
Note 1:
Where "plus" is shown between two buttons, both buttons must be
pressed together
Note 2:
Where "or" is shown between two buttons, either buttons can be
pressed to either increase or decrease setting
Note 3:
Where "then" is shown between rows of buttons, follow
instructions for top row first before moving on to instructions for
second row
Note 4:
When using
,
, + or - buttons during programing, a single
press of the button changes the value by one unit, if the button is
held down the value will continue to change until the button is
released.
(if flashing, Optimum Start Control is in operation)
Cooling Output Indicator (if flashing,
cooling delay operating)
LCD
DISPLAY
Event Number Indicator
when programing
Low Battery
(flashing)
Fan Output & Speed Indicator
(if flashing, fan about to come on)
Cooling Set Point
A
UTO
Thermostat
H
Mode Select
EAT
C
OOL
O
FF
A
UTO
O
N
S
ART
Fan Mode
Select
Clock Display/Measured
Temperature Display
1
2
3 4 5 6 7
O TU WE TH FR SA SU
HP8000 Heatpump
Thermostat (cover
flap removed)
HC8000 Heat/Cool
Thermostat (cover
flap removed)
HC8000 Heat/Cool
Thermostat 3 Speed
fan (cover flap
removed)
Heating Set Point
(if flashing, Optimum Start Control is
in operation)
Heating Output Indicator (if flashing,
heating delay operating)
Increase Temperature
Room/Outdoor Temperature (if flashing
remote sensor is faulty
Decrease
Temperature
Vacation Mode
Day of Week
1

Advertisement

loading

Summary of Contents for Danfoss HC8000 Series

  • Page 1: User Instructions

    User Instructions Electronic Programable Room Thermostats HC8000 Series Heat/Cool & HP8000 Heat Pump Thermostats Product Features HP8000 Heatpump • 7-day, 5/2-day or 24 hour programing, set by installer Thermostat (cover • flap removed) 2, 4 or 6 programed events each day, set by installer (can also be set up as regular non-programable thermostat) •...
  • Page 2 LCD DISPLAYS BUTTONS USER PREFERENCES Before programing the thermostat it is recommended that the user preferences, as regards clock display and temperature scale, are set. Details of the available user preferences are shown below: NEXT COPY A.1. Display Time: to permanently display time press both NEXT and COPY and hold for plus 2 seconds.
  • Page 3: Lcd Displays

    LCD DISPLAYS BUTTONS D.3. OPTIONAL - programable fan/occupancy operation : If the programable fan/ occupancy option has been enabled by the installer, the operation of the fan can be set for each event. Additionally each event can be programed as building occupied or unoccu- pied.
  • Page 4 LCD DISPLAYS BUTTONS DAILY USE INSTRUCTIONS SELECTING THE THERMOSTAT OPERATING MODE USING MODE BUTTON Mode The operating mode of the thermostat can be changed by pressing the MODE button. The available modes are as follows: · Auto: The thermostat selects heat or cool as required Reminder - This mode is only available if the building owner or installer has set the thermostat to allow auto change-over mode ·...
  • Page 5 BUTTONS LCD DISPLAYS H.4. Should Heat only or Cool only be required, use MODE button to select required service Mode H.5. Should OFF be required, use MODE button to select “Off” Caution – Freeze protection is not provided in OFF mode Hold mode with Off selected Selecting the Fan Operating Mode while in Hold mode 80˚...
  • Page 6: Other Features And Functions

    LCD DISPLAYS BUTTONS OTHER FEATURES AND FUNCTIONS & DISPLAYING OUTDOOR TEMPERATURE CLOCK K.1. All models can be connected with an outdoor temperature sensor. In non-heat- pump versions this is used solely to provide temperature indication. In heat-pump models the feature can also be used to improve heat-pump performance K.2.
  • Page 7 SELECTING FAN SPEED SETTING FAN SPEED / Reminder - Applies only to HC8000 series 3-speed fan models N.1. To change fan speed, press FAN-SPEED button. Bars on the fan symbol of the LCD indicate the selected fan speed...
  • Page 8 Thermostat setting template, 7-day programing with 6 events each day Event Setting Time/ temp Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 Monday Tuesday Wednesday Thursday Friday Saturday Sunday Column 1 Column 6 “If the thermostat has been set for 5/2-day operation, use column 1 to record settings for days 1-5 and column 6 to record settings for days...
  • Page 9 Thermostat setting template, 7-day programing with 4 events each day Event Setting Time/ temp Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 Monday Tuesday Wednesday Thursday Friday Saturday Sunday Column 1 Column 6 “If the thermostat has been set for 5/2-day operation, use column 1 to record settings for days 1-5 and column 6 to record settings for days...
  • Page 10 Occupancy: Danfoss can accept no responsibilty for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.

This manual is also suitable for: