Remedy in case of faults

9. Remedy in case of faults
Type of malfunction
Unit does not start
Unit does not suck in
Unit sucks, but the
pressure does not
build up
Coating material exits
at the top of the fluid
section
Possible cause
No voltage applied.
Pressure setting too low.
ON/OFF switch defective.
Relief valve is set to SPRAY
( p spray).
Filter projects over the fluid
level and sucks air.
Filter clogged.
Suction tube is loose, i.e. the
unit is sucking in outside air.
Tip heavily worn.
Tip too large.
Pressure setting too low.
Filter clogged.
Coating material flows
through the return hose when
the relief valve is in the SPRAY
( p spray) position.
Packings sticky or worn.
Valve balls worn.
Valve seats worn.
Upper packing is worn.
Piston is worn.
g
Measures for eliminating the malfunction
Check voltage supply.
Turn up pressure control knob.
Replace
Set relief valve to PRIME (k circulation).
Refill the coating material.
Clean or replace the filter.
Clean connecting points. Replace O-rings if
necessary. Tighten suction tube.
Replace
For selection of a smaller tip, see Tip table on
Page 46.
Turn pressure control knob to a higher number.
Clean or replace the filter.
Remove and clean or replace relief valve.
Remove and clean or replace packings.
Remove and replace valve balls.
Remove and replace valve seats.
Remove and replace packing.
Remove and replace piston.
ProSpray 30 • 34