Chapter 3 Rack Installation
3.3 Installing Drive Enclosure
■ For regions other than EMEA&I
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Installation-
(4)
For the right slide rail, insert the pins in the holes of the rear pillar, and secure the other
side of the slide rail to the front pillar in the same way as the left slide rail.
(5)
Push the M5 cage nuts into the 2nd holes of the front rack pillars above the base line of
the drive enclosure.
The M5 centering screw and M5 pan head screw positions for the slide rails and 2U
Bracket are determined relatively to the base line of the drive enclosure.
Tighten the screws referring to the following figure.
[Left]
3rd position
(M5 screws)
2U
Controller enclosure
1st position
(M5 screws)
controller enclosure
(1)
Adjust the sizes of the rack rail (for left side) and the rack rail (for right side) to fit the
rack.
Loosen the M4 screws to adjust the length of the rack rails to match the distance
between the front and rear rack pillars. Leave the M4 screws slightly unscrewed, as the
rack rails must be attached to the rack before they can be completely tightened.
Bracket L (for left side)
"L" is stamped on the inner
side of the left rack rail.
[Left]
(Front rack pillars)
Copyright 2014 FUJITSU LIMITED
[Right]
3rd position
(M5 screws)
1st position
(M5 screws)
Base line of
Rack rails
(Brackets)
(Rear rack pillars)
Loosen the M4 screws,
and adjust the rack rails to
the depth of the rack.
Bracket R (for right side)
"R" is stamped on the inner
side of the right rack rail.
[Right]
58
M5 Centering screw (10mm)
M5 Cage nut
M5 Pan head screw (10mm)
P3AM-5502-05ENZ0