Chapter 2 Components
2.1 Controller Enclosure
●
Part explanation
•
LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
•
iSCSI port (0 (left), 1 (right))
These ports are RJ45 connectors for LAN cables.
•
PWC port
This port is used for power synchronization.
•
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
•
LEDs
The states of LEDs are listed below.
Table 2.5
SCU STATUS
IDENTIFY
DI (OUT) LINKUP
UNIT READY/
FAULT
MASTER
ACT
LINK
FAULT
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Installation-
Status and meanings of each LED (iSCSI model controller)
LED name
LED status
(green)
(blinks green)
(blinks blue)
(off)
(green)
(green)
(orange)
(green)
(green)
(green)
(orange)
Copyright 2014 FUJITSU LIMITED
The SCU is in normal status.
SCU is charging.
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
The link between the DI (OUT) port and the
destination has been established.
The controller is in normal status.
•
The controller is performing the initial setup after
the power is turned on.
•
The controller is in error status.
The controller is set as a Master CM.
The controller is sending or receiving data via the LAN
port (for operation management).
•
The link between the LAN port (for operation
management) and the destination has been
established.
•
The link between the iSCSI port (host interface
port) and the destination has been established.
•
The controller is performing the initial setup after
the power is turned on.
•
The iSCSI port (host interface port) is in error
status.
35
Controller status
P3AM-5502-05ENZ0