Electrical Requirements - Magic Chef MCSCWD20W User Manual

2.0 cu. ft. ventless washer dryer combo
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements

• Connect to a Grounded 3 prong outlet with an
individual 12 amp branch circuit protected by a 12 amp
circuit breaker.
• Connect to individual branch circuit.
• Do not remove grounding prong.
• Do not use an adapter.
• Do not use an extension cord.
• Failure to follow these instructions can result in
electrical shock, fire or death.
1. A120V~60Hz, AC only,15-20amp, fused electrical supply is required. A time-delay fuse or circuit
serving only this appliance must be provided .
2. This appliance is equipped with a 3 prong grounded power plug.
3. To minimize possible shock hazard, the power plug must be plugged into a mating 3 prong
grounding type outlet and grounded in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and obligation of the owner to have the
properly grounded outlet installed by a qualified electrician.
4. If codes permit and a separate ground wire is used, it is recommended a qualified electrician
determine if the grounding path is adequate.
5. Do not ground to a gas pipe .
6. Check with a qualified electrician if you are not sure the washer is properly grounded
7. Do not have a fuse in the neutral or ground circuit.
WARNING
Electrical Shock Hazard
10