12.
AUDIO MONITOR OUT connector
This connector outputs the audio signal (CH1 to CH8)
that is selected with the MONITOR button and the
METER SELECT switch.
13.
DIGITAL AUDIO IN/OUT connectors
These connectors input and output digital audio
signals compliant with the AES/EBU standard.
14.
ANALOG COMPOSITE VIDEO IN/OUT connectors
Input/output analog composite video signals.
IEEE 1394 Digital Interface
■ Basic Setup
Make sure that setup menu No. 882 (DIF IN CH) and No. 883
(DIF OUT CH) on this unit are set to “AUTO.”
◆ NOTE:
• Only signals that comply with the format selected in setup menu No.
020 (SYS FORMAT) can be input. When the SYS FORMAT is 480i
(576i at 50 Hz), operations are limited to setup menu No. 024 (REC
FMT (SD)) settings.
• The selected recording format and the format of a recording on an
inserted P2 card determine the output format.
• Select CH1/CH2 or CH3/CH4 as the output audio channels (in
DVCPRO/DV).
■ Precautions
• Connect this unit to only one other device.
• If the E-92 warning (1394 INITIAL ERROR) appears,
reconnect the connecting cable or turn the power off and
back on again.
• AV signals may be disrupted when connected devices are
turned on and off or when the interface cable is connected
or disconnected.
• It may take the system a few seconds to stabilize after
switching input signals or changing modes. Start recording
after the system has stabilized.
• The following applies to recordings made via the IEEE 1394
digital interface as well as to the signals it outputs.
- The audio level control knobs on the front panel do
not work.
- The settings in menu No. 680 (CC (F1) BLANK) and
No. 681 (CC (F2) BLANK) regarding blanking
periods are ignored, and no blanking is effectuated.
- Video and audio recording and EE type video and
audio of signal inputs other than 1x speed playback
signals are not guaranteed.
• Pressing the REC button during playback to switch to the EE
mode may interfere with the IEEE1394 digital interface. To
output EE mode, set setup menu No. 122 (STOP EE SEL) to
EE.