Aim the laser beam at the target surface. Push
the measuring button 5 again to initiate the
measurement.
In the continuous measurement mode, the
measurement already starts upon first
actuation of the measuring button 5.
The measured value appears after 0.5 to 4
seconds. The duration of the measurement
depends on the distance, the light conditions
and the reflection properties of the target
surface. The end of the measurement is
indicated by a signal tone. The laser beam is
switched off automatically upon completion of
the measurement.
When no measurement has taken place
approx. 20 seconds after sighting, the laser
beam is switched off automatically to save the
batteries.
Selecting the Reference Point
(see figures B–C)
For measuring, it is possible to select from two
different reference points:
• The rear edge of the Distance Measurer
(e.g., when placing the Distance Measurer
flush against a wall),
• The front edge of the Distance Measurer
(e.g., as when measuring from the edge of a
table onward),
To select the reference point, push button 9
until the required reference point is indicated in
the display. Each time after switching on, the
rear edge of the Distance Measurer is preset
as the reference point.
Changing the Unit of Measure
The unit of measure can be changed any time
for display of the measured values, even for
already measured or calculated values.
For display of the current
length
values, the units of
measure shown opposite
are available.
Area and volume values
as
measured values can
only be displayed in "ft" or "m".
To change the unit of measure, push button 2
until a new unit of measure is displayed.
The unit-of-measure setting is retained when
switching the Distance Measurer on or off.
Metros digitales Laser DLR130K Bosch manual ingles www.viaindustrial.com
measurement
well
as
stored
-10-

MEASURING MODES

Length Measurement
For length measurements, push button 13.
The indicator for length measurement
appears in the display.
Push the measuring
button 5 once for sighting
and once more to take
the measurement.
The measured value is
indicated at the bottom in
the display.
Area Measurement
For area measurements, push button 12. The
indicator for area measurement
the display.
Afterwards, measure the
length and the width, one
after another, in the same
manner as a length
measurement. The laser
beam remains switched
on between both measurements.
After taking the second measurement, the
area/surface is automatically calculated and
displayed. The last individual measured value
is indicated at the bottom in the display, while
the final result is shown at the top.
appears in