Consumable Errors

Install or Reseat Imaging Unit

Remove and reseat the Imaging Unit.
Ensure that Door C is fully closed.
Cycle printer power.
If the problem persists, follow the procedure below
Troubleshooting Reference Table
Applicable Parts
Imaging Unit, PL 9.1.3
Troubleshooting Procedure Table
Step
Actions and Questions
1
Remove the Imaging Unit.
Inspect the printer cavity for damage,
foreign material and loose toner under the
auger area which could prevent the
Imaging Unit from being seated properly.
Is there foreign material or damage?
2
Inspect and reseat the Imaging Unit
checking for possible defects or damage.
3
Remove the left cover.
Check the Gear Slide and the Rack V for
damage or misalignment.
See "Toner Cartridge Holder Unit
Assembly (PL 10.1)" on page 8-77 for
more information.
4
Verify the CRUM connector is not
damaged or improperly connected.
5
Check the CRUM Harness for continuity.
See "Laser Unit" on page 10-22.
6
Check the EEPROM Harness for
continuity.
See "Laser Unit" on page 10-22
3-42
Wiring and Plug/Jack Map References
"Laser Unit" on page 10-22
"Fuser Assembly" on page 10-21
Phaser 6250 Color Laser Printer Service Manual
Yes
Remove foreign
materials.
Vacuum out loose
toner if found.
Replace the Imaging
Unit, PL 9.1.3.
Damage can occur if
the Gear and Rack are
not in the proper
position. With Door C
open, push the Rack V
up as far as it can go
and then reinstall the
gear slide.
Replace the Plate
Dispenser Left,
PL 10.1.9.
Go to Step 6.
Replace the Engine
Control Board,
page 8-107.
No
Go to Step 2.
Go to Step 3.
Go to Step 4.
Go to Step 5.
Replace CRUM
Harness Assy,
PL 10.1.15.
Replace
EEPROM
Harness Assy,
PL 13.1.10.