Product Data Sheets - KitchenAid 2308307 Use And Care Manual

Side by side refrigerator
Table of Contents

Advertisement

Available languages

Available languages

This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
Asbestos
99%
Live Cysts
>99.95%
Turbidity
0.5 NTU
Alachlor
0.002 mg/L
Endrin
0.002 mg/L
Ethylbenzene
0.7 mg/L
Lindane
0.002 mg/L
Monochlorobenzene
0.6 mg/L
Tetrachloroethylene
0.005 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F
(20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement cartridge T1RFWB2, part #4396711.
2005 suggested retail price of $39.99 U.S.A./$49.99 Canada.
Prices are subject to change without notice.
Model T1WB2L: When the filter indicator light changes from
green to yellow, order a new filter. When the filter indicator light
changes from yellow to red, it is recommended that you replace
the filter.
Model T1WB2: Change the water filter cartridge every 6 months
depending upon your usage. If the water flow to the water
dispenser or ice maker decreases noticeably before 6 months
have passed, replace the water filter cartridge more often.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the back cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
††
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.

PRODUCT DATA SHEETS

Base Grille Water Filtration System
Model T1WB2L/T1RFWB2 Capacity 200 Gallons (758 Liters)
Model T1WB2/T1RFWB2 Capacity 200 Gallons (758 Liters)
Tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction
of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos,
Lindane, Tetrachloroethylene, Endrin, Alachlor, Monochlorobenzene and Ethylbenzene.
Average
Influent
2.0 mg/L
3533333#/mL
Average
Influent
150 ug/L
157 ug/L
0.0058 mg/L
0.0057 mg/L
15 ug/L
1750 ug/L
15 ug/L
10 ug/L
101 MFL
120,000/L
11.4 NTU
41.3 ug/L
5.9 ug/L
1867 ug/L
1.9 ug/L
2.0 ug/L
14.2 ug/L
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.08 mg/L
At least 10,000
22000 #/mL
particles/mL
Influent Challenge
Maximum
Concentration
Effluent
0.15 mg/L ± 10%
1.0 ug/L
0.15 mg/L ± 10%
2.0 ug/L
0.006 mg/L ± 10%
0.0002 mg/L
0.006 mg/L ± 10%
0.0002 mg/L
0.015 mg/L ± 10%
0.5 ug/L
1.8 ± 10%
1.0 ug/L
0.015 ± 10%
1.0 ug/L
0.009 mg/L ± 10%
2 ug/L
7
8
††
10
to 10
fibers/L
0.17 MFL
50,000/L min.
8/L
11 ± 1 NTU
0.41 NTU
0.04 ± 10%
0.2 ug/L
0.006 ± 10%
0.5 ug/L
2.1 ± 10%
0.70 ug/L
0.002 ± 10%
0.02 ug/L
2.0 ± 10%
0.0005 ug/L
0.015 ± 10%
0.5 ug/L
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum %
Effluent
Reduction
2.0 mg/L
95.93
**
11567 #/mL
99.38
Average
Minimum %
Effluent
Reduction
1 ug/L
99.33
1.08 ug/L
98.72
0.0002 mg/L
96.53
0.0002 mg/L
96.5
0.5 ug/L
96.67
1.0 ug/L
99.94
1.0 ug/L
93.33
2 ug/L
80.8
0.17 MFL
99.83
1/L
99.99
0.24 NTU
96.4
0.2 ug/L
99.52
0.3 ug/L
91.5
0.0588 ug/L
99.96
0.02 ug/L
98.93
0.0005 ug/L
99.98
0.5 ug/L
96.47
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
0.5 gpm (1.9 L/min.) @ 60 psi.
Average %
Reduction
97.36
99.67
Average %
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
27

Advertisement

Table of Contents
loading

Table of Contents