Gas Conversions; Lp Gas Conversion - KitchenAid DUALFUEL RANGES Installation Instructions Manual

30" (76.2 cm) freestanding and slide-in dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

If range does not operate, check the following:
Household fuse is intact and tight, or circuit breaker has not
tripped.
Gas valves are turned to the "open" position.
If the gas supply line shutoff valve is open, press the OFF
button on the oven control panel and contact a qualified
technician.
Gas conversions from Natural gas to LP gas; or from LP gas to
Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.

GAS CONVERSIONS

1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect power.
3. Remove warming drawer. See the "Remove Warming
4. Remove access cover from the gas pressure regulator.
Gas pressure regulator
5. Remove the access cap by using a wrench, turning the
6. Remove spring retainer from the cap by pushing against the
7. Turn over the spring retainer so the "LP" is showing on the
8. Snap the spring retainer back into the cap.
Electrical supply is connected.
See "Troubleshooting" in the Use and Care Guide.
When the range has been on for 5 minutes, check for heat. If
range is cold, turn off the range and contact a qualified
technician.
To Convert Gas Pressure Regulator
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
Drawer" section for instructions. Locate gas pressure
regulator at rear of warming drawer compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
access cap counterclockwise.
flat side of the spring retainer. Look at the spring retainer to
locate the "NAT" or "LP" position.
bottom.
B
C
19